When I first started making my own isopod enclosures, my ventilation solution was fairly straightforward. I used a 1¾-inch (44 mm) holesaw to cut ventilation holes into my bins. On occasion, I also used a 52 mm holesaw. I then covered the holes with drain tape.

44 mm holesaw used to create ventilation holes in isopod enclosures
Figure 1. A 44 mm holesaw used to create ventilation openings in plastic isopod enclosures. Photograph: Isopop (2026). Original photograph, available at Isopop.

I covered these openings with drain tape, a product that I even stocked on the Isopop website for a while.

Drain tape used as ventilation mesh on an isopod enclosure
Figure 2. Drain tape used to cover ventilation openings in an isopod enclosure. Photograph: Isopop (2026). Original photograph, available at Isopop.

However, I soon discovered that drain tape had a number of significant shortcomings.

The problems with drain tape

There were three main problems with using drain tape:

  • It is plastic. A beetle managed to eat through the mesh and gain access to an enclosure. I even came across a Reddit discussion where someone reported a mouse getting into their enclosure through a plastic ventilation mesh. An absolute disaster!
  • The openings are relatively large. Although the mesh provides ventilation, it does not reliably prevent smaller insects, particularly ants, from entering the enclosure.
  • The adhesive does not last. Drain tape is generally secured using double-sided adhesive, which can gradually lose its grip and begin to detach from the enclosure.

I initially tried to address the problem of the relatively large mesh openings by applying a second layer of tape. Unfortunately, this was messy and imprecise. In some places, the openings in the two layers lined up, effectively defeating the purpose of adding the second layer in the first place.

The next problem was the adhesive. As the tape started becoming unstuck, I tried to resolve this by adding additional sticky tape and masking tape around the edges.

Drain tape beginning to detach from a plastic enclosure
Figure 3. Drain tape beginning to detach from the surface of an enclosure, exposing the limitations of adhesive-based ventilation. Photograph: Isopop (2026). Original photograph, available at Isopop.
Additional sticky tape applied to secure ventilation mesh
Figure 4. An attempt to secure ventilation tape using additional adhesive tape. Photograph: Isopop (2026). Original photograph, available at Isopop.

This created further problems. The additional adhesive made the area even stickier, while the overlapping tape continued to partially obstruct the ventilation openings.

Then came the incident that finally convinced me that this approach had to go.

The sticky-tape disaster

A few days later, I was horrified and genuinely devastated to discover that some of my mancae had managed to use the sphagnum moss as a ladder to reach the small ventilation holes. They had made their way through the openings and become trapped on the sticky tape.

Isopod mancae trapped on sticky tape around an enclosure ventilation opening
Figure 5. The sticky-tape disaster: isopod mancae trapped on exposed adhesive around a ventilation opening. Photograph: Isopop (2026). Original photograph, available at Isopop.

This was particularly upsetting. Ventilation is supposed to improve the environment inside an enclosure, not introduce a hazard that can injure or kill the animals living in it.

After consulting with members of the local WhatsApp Isopods and Inverts SA community, I came to realise that adhesive-backed drain tape was simply not a suitable long-term solution. Properly fitted ventilation vents offered a much better alternative.

Moving to proper mesh vents

I reached out to Renate at Isopod Farms to discuss obtaining custom-sized ventilation vents. Her existing 28 mm mesh vents were a good starting point, but I wanted something that would fit the 44 mm holes I was already cutting into my bins.

I arranged a custom order for 44 mm vents, and very soon I had my first proper set of ventilation fittings.

Custom ordered 44 mm mesh ventilation vents
Figure 6. The custom-ordered 44 mm mesh ventilation vents from Isopod Farms. Photograph: Isopop (2026). Original photograph, available at Isopop.

These were a significant improvement, but lessons learned from my Dairy Cow Disaster highlighted an opportunity to improve on the standard vent design.

Designing an improved ventilation vent

I decided to design my own vent, with a number of specific improvements in mind. Rather than simply reproducing an existing design, I wanted to address some of the practical shortcomings I had encountered when using and installing ventilation fittings.

My design objectives were:

  • An integrated shelf: A small shelf on the inside of the vent, providing isopods with somewhere to sit and congregate around the ventilation opening.
  • A larger base plate: The base plate needed to be large enough to cover from 44 mm to 55 mm holes.
  • A larger, easy-grip nut: The nut needed to be easy to handle and tighten, whilst still accommodating the different hole sizes.
  • An improved mesh retaining plate: The mesh plate needed to be correctly sized so that it would remain securely in position during tightening rather than popping out.
  • Improved metal mesh sizing: I wanted to maximise the available mesh area for airflow while still providing an effective physical barrier against ants and other unwanted insects.
  • A sturdier construction: I opted for 2 mm thick plastic to give the finished vent a more substantial and durable feel.

Selecting the optimal metal mesh

One of the most important considerations in designing a ventilation vent is selecting the appropriate mesh. There is an inherent trade-off between ventilation and pest exclusion. Larger openings allow more air to pass through, but also make it easier for unwanted insects, particularly ants, to enter an enclosure. Conversely, finer mesh provides a smaller physical opening but can restrict airflow.

My initial research suggested that mesh in the 40–50 mesh range could provide a reasonable compromise between insect exclusion and ventilation. However, I wanted to investigate finer mesh options, particularly given my previous experiences with ants and other unwanted insects entering enclosures.

Mesh count describes the number of openings per linear inch. The higher the number the finer the mesh openings, so the higher the number the smaller the holes get. The actual aperture, or clear opening, also depends on the diameter of the wire used to construct the mesh.

Research into insect-proof screening has demonstrated that mesh geometry, aperture dimensions and physical porosity all influence both insect exclusion and airflow. Chouinard demonstrated that the physical characteristics of insects, together with the size and shape of mesh openings, influence their ability to pass through screening [Chouinard et al. 2023]. López-Martínez investigated how the geometric characteristics of insect-proof screens influence their aerodynamic performance [López-Martínez et al. 2020].

I ultimately decided on 120-mesh stainless steel. By choosing 120 mesh, I wanted to retain relatively small openings to provide a physical barrier against unwanted insects, without unnecessarily restricting ventilation. In other words, I wanted to use the finest mesh that offered a practical balance between pest exclusion and airflow, rather than simply selecting the finest mesh available.

Stainless steel was another deliberate choice. Unlike the plastic drain tape I had previously used, stainless steel provides a more robust physical barrier and avoids the vulnerability to chewing that I had experienced with drain tape.

Of course, mesh count alone does not tell the whole story. Wire diameter, actual aperture and open-area percentage all contribute to the final airflow characteristics. 120 Mesh is easy to see through, and I can feel a breeze through the mesh, and look forward to seeing my Porcellio Laevis 'Dairy Cow' and Cubaris Murina sp. 'Glacier' sitting on the ledge. I intend to measure the airflow through the finished vent using an anemometer, rather than relying entirely on practical observations.

The choice of 120 mesh was an important part of the design, and one that I hope have already validated through practical testing. I have ordered an handheld anemometer, and soon I will be able to add some testing results.

Initial concept for an improved 3D printed isopod ventilation vent
Figure 7. Initial design concept showing the proposed improvements to the ventilation vent. Photograph: Isopop (2026). Original photograph, available at Isopop.

Designing in OpenSCAD

I created the initial design using OpenSCAD, a fantastic open-source 3D CAD application that allows you to construct objects using mathematical descriptions and parametric modelling.

One of the particularly useful features of OpenSCAD is its ability to work with libraries of reusable algorithms and functions. For my project, the threading functionality was especially useful, allowing me to create the screw and nut components parametrically.

Using a parametric approach meant that I could adjust dimensions and tolerances in the source design rather than manually redesigning individual components every time something needed changing.

Once I had a workable initial design, I exported the components as STL files ready for 3D printing.

First 3D printed prototype of the custom ventilation vent
Figure 8. The first physical print of the ventilation vent design. Photograph: Say it... Creations (2026). Original photograph, available at Isopop.

Rapid prototyping and iteration

For the printing and prototyping process, I approached Michelle at Say it... Creations, who has multiple 3D printers and takes on custom printing projects.

This turned out to be an excellent arrangement. Michelle was incredibly quick to print the STL files and, importantly, could provide immediate feedback on how the parts fitted together. This allowed me to work through multiple design iterations without needing to own a 3D printer myself.

The first print immediately highlighted a problem: the nut was too small.

First ventilation vent prototype showing an undersized nut
Figure 9. Initial prototype revealing that the nut was too small for comfortable handling and installation. Photograph: Say it... Creations (2026). Original photograph, available at Isopop.
First prototype showing the ventilation vent plate
Figure 10. The initial printed plate component of the ventilation vent. Photograph: Say it... Creations (2026). Original photograph, available at Isopop.

Based on Michelle's feedback, I made several adjustments to the design, changing parameters and fine-tuning dimensions to improve the fit.

One of the challenges with 3D-printed threaded components is getting the tolerances right. A thread that looks perfectly fine in the CAD model may not necessarily work as intended once printed. Material behaviour, printer calibration and the tolerances of the mating components all play a role.

Rather than making one small adjustment at a time and hoping for the best, I started producing multiple size variations for testing.

Second design iteration with alternative ventilation vent sizing
Figure 11. Second design iteration, testing alternative dimensions and component sizing. Photograph: Say it... Creations (2026). Original photograph, available at Isopop.

I eventually started providing Michelle with STL files containing multiple size options. For example, I produced variations ranging from 1-bump through to 10-bump, representing different thread sizing and tolerance options.

This allowed several alternatives to be printed together, after which we could physically test the combinations and select the best-fitting components. It was a much more efficient way of finding the right dimensions than repeatedly printing a single variation.

Third ventilation vent iteration showing multiple printed options
Figure 12. Third design iteration, with multiple component variations printed for comparison. Photograph: Say it... Creations (2026). Original photograph, available at Isopop.
Third iteration showing different thread and component sizing options
Figure 13. Comparing the different sizing options produced for the third design iteration. Photograph: Isopop (2026). Original photograph, available at Isopop.
Testing alternative sizes of the third ventilation vent iteration
Figure 14. Physical testing of the third iteration to identify the best-fitting component combinations. Photograph: Isopop (2026). Original photograph, available at Isopop.

Testing in real enclosures

As the design progressed, I moved beyond simply checking whether the individual components fitted together. It was important to test the vents in actual enclosures, under the conditions in which they would eventually be used.

One of the things I discovered was that the diameter of the base plate needed to be increased to 60 mm. This provided better coverage, particularly when working with the larger holesaw openings.

Fourth iteration showing alternative ventilation plate diameters
Figure 15. Fourth design iteration, testing alternative plate diameters before settling on a 60 mm base plate. Photograph: Isopop (2026). Original photograph, available at Isopop.

I also tested the vents in a variety of bin configurations. This included different hole positions, such as openings close to the edge of a bin, near corners and in enclosure lids.

Different container manufacturers can also introduce small variations in wall thickness and geometry. I therefore tested the design in both Addis and Hobbylife containers to make sure that the final dimensions would work across the different bins I use.

After extensive testing, I was happy with the fit and settled on the nut dimensions that worked best across these different configurations.

Fifth ventilation vent iteration showing different nut options
Figure 16. Fifth design iteration, comparing the final nut sizing options following testing across different enclosure configurations. Photograph: Isopop (2026). Original photograph, available at Isopop.

The finished design

After five iterations, considerably more than I originally anticipated, I finally arrived at a design that I am happy with.

The process has been a great learning experience. What started as a simple attempt to replace drain tape with a better ventilation solution developed into a complete redesign, with improvements to the mounting system, mesh retention, plate dimensions, durability, grip and overall construction.

Most importantly, the final design addresses the practical problems that prompted the project in the first place. I wanted a ventilation solution that was sturdy, easy to install, properly secured and suitable for the different enclosure configurations I use.

I am pleased to announce that the finished Isopop 44–55 mm Mesh Vent is now available to purchase! We are offering three colours: White, Black and Light Purple. If you have something else in mind, we can even make a custom colour for you! 😆

Final 3D-printed ventilation vent components with stainless-steel mesh installed
Figure 17. The final 3D-printed ventilation vent components, assembled with the stainless-steel mesh installed. Photograph: Isopop (2026). Original photograph, available at Isopop.
Completed Isopop ventilation vent in white
Figure 18. The completed Isopop ventilation vent, shown in the white colour option. Photograph: Isopop (2026). Original photograph, available at Isopop.

Hopefully, sharing the development process will also give other isopod keepers some ideas about enclosure design and the benefits of experimenting with and improving the equipment we use.

Happy keeping!